Fire risk assessment reviews: how often are they needed? (UK)
There is no fixed interval in law. Review the assessment regularly, and whenever there is reason to believe it is no longer valid, for example after building work, a change of use, a fire or a near miss. In England, the full assessment has had to be recorded in writing since October 2023.
Every check and its frequency
Covers every premises within the Fire Safety Order in England and Wales, the common parts of blocks of flats included.
| Check | How often | Basis | Status | Source |
|---|---|---|---|---|
| Review the fire risk assessment | Regularly; no fixed interval set in law. Also whenever it may no longer be valid or there has been a significant change | Article 9 of the Regulatory Reform (Fire Safety) Order 2005, as amended by the Building Safety Act 2022. Regular review is a legal requirement, but no fixed interval is set; each assessment and review has to be recorded in full. | Law | The Regulatory Reform (Fire Safety) Order 2005, article 9 checked |
No fixed review date is set in law: review the assessment regularly and after any significant change, fire or near miss. Since October 2023, every responsible person in England has had to keep a full written record of the assessment, however many employees they have.
What it is about
A fire risk assessment sets out what could start a fire, who would be at risk and what precautions will keep people safe. All the other checks in our compliance guides flow from it: the assessment determines which fire alarm, emergency lighting and fire doors a building needs.
Under article 9 of the Regulatory Reform (Fire Safety) Order 2005, it is a legal requirement for all non-domestic premises in England and Wales, and for the common parts of blocks of flats.
Everyone who could be affected by a fire must be considered, not just employees: visitors, contractors and anyone who may need help to get out, such as disabled people. The assessment also sets the measures that the building's other fire checks then keep in place, from testing the fire alarm to emergency lighting checks and fire door inspections.
The checks one by one
Review the fire risk assessment
Regularly; no fixed interval set in law. Also whenever it may no longer be valid or there has been a significant change · Law
Article 9 of the Regulatory Reform (Fire Safety) Order 2005, as amended by the Building Safety Act 2022. Regular review is a legal requirement, but no fixed interval is set; each assessment and review has to be recorded in full. Source, last checked .
Whose duty it is, and who can carry it out
The responsible person, normally the employer, or the owner or whoever controls the premises. They may do the assessment themselves or appoint someone to help, and in England anyone appointed to help has to be competent.
What to record
In England, every responsible person has had to keep a written record of the whole assessment since October 2023, however many employees they have. The record sets out the findings and the measures taken or planned, and is updated at each review.
How to run it well
- Carry out a review after any significant change, such as building works, a change of use, more people, new equipment or new processes.
- Carry out a review after a fire or a near miss.
- As the law sets no review date, choose your own and record it.
- Confirm the actions from the previous assessment were completed, and note when.
- Tell employees about the findings and, in a shared building, the other people responsible for fire safety there.
Building types it applies to
Fire risk assessment is included in our compliance calendar for every building type we cover. Every calendar puts it next to the other checks that building usually needs.
Managing it in software
A CAFM system can schedule these checks, remind the person responsible, and file every certificate or log entry against the asset, keeping the evidence together for an inspector or insurer. The table sets out what each product states in its documentation.
| Software | Compliance certificates and expiry tracking | Planned maintenance (PPM) scheduling | SFG20 maintenance library | Contractor portal | QR or NFC asset tags |
|---|---|---|---|---|---|
| Joblogic | Yes | Yes | Yes | Partly | Yes |
| Infraspeak | Yes | Yes | Yes | Yes | Yes |
| Planon | Partly | Yes | Yes | Partly | Yes |
| Concerto | Yes | Yes | Yes | Yes | Yes |
| Service Works Global | Partly | Yes | Yes | Partly | Yes |
| MaintainX | Partly | Yes | Not confirmed | Partly | Yes |
| Snapfix | Yes | Yes | Not confirmed | Partly | Partly |
For the products ordered for this job, see the the compliance software shortlist, or read what planned preventive maintenance is.
Common questions
How frequently does a fire risk assessment need reviewing?
No fixed interval is set in law. It has to be reviewed regularly, and whenever there is reason to believe it is no longer valid or a significant change has taken place.
Must a fire risk assessment be recorded in writing?
Yes in England, since October 2023, for every responsible person, however many employees they have.
Can I carry out the fire risk assessment myself?
Yes, provided you are competent to do so. In England, anyone you appoint to help must also be competent.
What should prompt a review?
A significant change to the building, how it is used or who is in it, a fire or near miss, or anything else suggesting the assessment is no longer valid.